Bacti-Cinerator Sterilizer YR06041: Result Interpretation and Measurement Reading Guide 2026
The Bacti-Cinerator Sterilizer YR06041 is a pivotal tool in any laboratory setting, providing rapid sterilization techniques crucial for various applications. Understanding how to interpret the results and accurately read measurements is essential for effective use. This guide aims to dissect the functionalities and specifications of the YR06041, equipping operators with the knowledge they need to maximize its potential.
Understanding the Functionality of the Bacti-Cinerator YR06041
The Bacti-Cinerator YR06041 operates on the principle of high-temperature sterilization, utilizing a heated center that can reach temperatures of approximately 825℃ ± 50℃. This high heat capacity ensures that tools such as inoculating loops and needles are sterilized in a matter of seconds, fundamentally transforming laboratory efficiency. The compact design and lightweight nature of the unit make it suitable for diverse laboratory environments, including anaerobic chambers.
Technical Specifications of YR06041
| Model | YR06040 | YR06041 (current) |
| Power | 110V/220V;150W | 110V/220V;240W |
| High Temperature Center | 825℃ ± 50℃ | |
| Standby Constant Temperature | Heating with two gears 400℃ / 850℃ | |
| Maximum Diameter of Sterilizers | φ 14mm | φ 35mm |
| Length of Sterilizer | 150 mm | 100 mm |
| Heating Time | 10min | |
| Operating Temperature Conditions | 5 ~ 40℃ | |
| Relative Humidity | ≤90% | |
| Dimensions | 175*130*185mm | 147*130*200mm |
| Net Weight | 1.3 kg | 1.4 kg |
Interpreting Results and Reading Measurements
Effective operation of the YR06041 requires a clear understanding of the measurement results displayed. The unit provides visual cues for both temperature settings and operational readiness. An operator must be familiar with the temperature readings, ensuring they align with expected sterilization standards.
For instance, if the displayed temperature is substantially lower than 400℃ during operation, it indicates a malfunction or incorrect setup. Furthermore, understanding the significance of the sterilization time, which ranges between 5 and 7 seconds, is vital. This efficiency is what sets the Bacti-Cinerator apart in a laboratory context.
Common Misinterpretations of Results
Misreading results can lead to ineffective sterilization, potentially compromising experiments or clinical procedures. Here are common pitfalls:
- Temperature Confusion: Operators might misinterpret the display, assuming a stable reading indicates operational readiness. A visual check of the sterilizer's heating element during the initial setup phase is essential.
- Timing Errors: The brief sterilization window must not be exceeded; otherwise, instruments may become damaged or overheated.
- Failure to Recognize Equipment Limits: Each sterilization session should adhere to the YR06041 specifications regarding tool sizes and weights.
Environmental Conditions for Optimal Performance
The operational efficacy of the YR06041 is significantly influenced by environmental conditions. Ensuring proper temperature (5 ~ 40℃) and humidity levels (≤90%) is essential. Here are additional guidelines for creating an ideal laboratory environment:
- Ventilation: Maintain adequate airflow around the sterilizer to prevent overheating.
- Clearances: Ensure sufficient space around the unit to facilitate maintenance and avoid obstructions that could affect performance.
- Stable Power Supply: The unit operates on either 110V or 220V; ensuring a stable electrical supply is crucial to its functionality.
Compatibility and Accessories for YR06041
Understanding the accessories that complement the YR06041 can enhance its usability. Compatible accessories include:
- Sterilization Loops and Needles: Custom-sized tools for optimal sterilization.
- Protective Covers: To safeguard the sterilizer from dust and heat exposure.
- Maintenance Kits: Essential for regular upkeep, ensuring longevity and performance.
Frequently Asked Questions
What is the maximum sterilization time for the Bacti-Cinerator YR06041?
The maximum sterilization time for the Bacti-Cinerator YR06041 is between 5 to 7 seconds, making it highly efficient for quick sterilization needs.
How often should I check the calibration of the YR06041?
Calibration should be checked regularly, ideally before each use, to ensure accurate temperature readings and effective sterilization.
What types of tools can be sterilized using the YR06041?
The YR06041 is designed for sterilizing inoculation loops, needles, and other small laboratory tools, with a maximum diameter of 35mm.
What are the environmental requirements for operating the YR06041?
The Bacti-Cinerator YR06041 operates optimally in temperatures ranging from 5 to 40℃ with a relative humidity of ≤90%.
Can the YR06041 be used in anaerobic conditions?
Yes, the YR06041 is suitable for use in anaerobic chambers, enhancing its versatility across various laboratory applications.
What should I do if the YR06041 does not power on?
If the unit does not power on, check the power supply and ensure all connections are secure. If the issue persists, consult the troubleshooting guide.
How can I maintain the YR06041 for longevity?
Regular maintenance includes cleaning the sterilizer, checking connections, and ensuring it remains free from obstructions to ensure optimal performance and longevity.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.