Description
The Patient Monitors YR02170 // YR02171 // YR02172 are advanced medical devices designed to provide comprehensive monitoring solutions. These monitors feature a multi-channel display, ensuring critical information is always visible at a glance. With a big font interface, healthcare professionals can easily read data, minimizing error risks. The devices offer ST and arrhythmia analysis, crucial for diagnosing and managing cardiac abnormalities. Additionally, features like drug dose calculation, titration table, dynamic OxyCRG view, and apnea alarms for respiration monitoring enhance their functionality. These monitors also include NIBP overpressure protection, ensuring patient safety. The option of a plug-in rechargeable battery and support for either wired or wireless connectivity makes the equipment highly adaptable to various medical settings.
Market Price
When considering an investment in patient monitors, a general market price range for devices with similar specifications is between $900 and $1,700. This range reflects the advanced technology and reliability seen in the Patient Monitors YR02170 // YR02171 // YR02172, positioning them as both competitive and worthwhile.
Frequently Asked Questions
What is the display capability of these monitors? These patient monitors feature a multi-channel display with a big font interface, facilitating easy and precise information reading.
Are these monitors suitable for wireless environments? Yes, they support both wired and wireless network connections, enhancing their versatility.
Advantages and Disadvantages
Among the key advantages are the monitors’ comprehensive measurements and analyses, such as ECG, heart rate, respiration, and more. The rechargeable battery feature allows for mobility and usage in various locations. Additionally, they are integrated with cutting-edge alarm systems. A potential downside could be the initial learning curve required to utilize all functionalities fully.
Product Use in the Field
In practical scenarios, these monitors are invaluable for continuous patient observation in intensive care units, operating rooms, and emergency wards. Their precise measurements of vital signs like ECG, respiration, and blood oxygen provide clinicians the information necessary to make informed decisions swiftly.
Recommendations
To maximize the use of these monitors, it is recommended to routinely calibrate the equipment and update the software. Healthcare facilities should also ensure that staff are adequately trained on all functionalities to leverage the full capabilities of the device.
Features
- Multi-channel display
- Big font interface
- ST and arrhythmia analysis
- Drug dose calculation and titration table
- OxyCRG dynamic view display
- Respiration monitoring with apnea alarms
- Alarm review, arrhythmia review
- NIBP overpressure protection
- Plug-in rechargeable battery, AC/DC available.
- Supporting wire or wireless network.
Technical Specifications
Model | YR02170 | YR02171 | YR02172 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) | ||
Connection method | I, II, III,AVR,AVL,AVF,V | |||
Lead Mode | 3 Leads (RA,LA,LL) | |||
Connection method | I, II,III | |||
Waveform | 1ch | |||
Gain | x250, x500, x1000, x2000 | |||
HR Range | Adult: 15~300bpm | |||
Neo/Ped | 15~350bpm | |||
Accuracy | ±1% or ±1bpm | |||
Resolution | 1bpm | |||
Sensitivity | >200(uVp-p) | |||
Differential input impedance | ≥5MΩ | |||
ST segment Monitoring Range | ||||
Measure Range | -2.0~+2.0mV | |||
Measure Accuracy | -0.8mV~+0.8mV | |||
Heart Rate | Measuring range | 0~350bpm | 20~300bpm | |
Accuracy | ±1bpm | |||
Resolution | 1bpm | |||
Sensitivity | >200UVp-p | |||
Respiration | Method | Impedance between R-F(RA-LL) | ||
Differential Input Impedance | >2.5MΩ | |||
Measuring Impedance Range | 0.3~3.0 MΩ | |||
Base line Impedance Range | 200~4000Ω | |||
Bandwidth | 0.1~2.5Hz | |||
Resp. Rate | Adult: 2~120BrPM | |||
Neo/Ped | 2~150BrPM | 0~150BrPM | ||
Resolution | 1 BrPM | |||
Accuracy | ±2 BrPM | |||
Alarm | 10~40S | |||
NIBP | Method | Oscillometric | ||
Mode | Manual/Auto/STAT | |||
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |||
Measuring Period in STAT Mode | 5 Min | |||
Pulse Rate Range | 40~240bpm | |||
Alarm Type | SYS, DIA, MEAN | |||
Resolution | ||||
Pressure | 1mmHg | |||
Accuracy | Maximum Mean error: 5mmHg | |||
Maximum Standard deviation | 8mmHg | |||
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse | ||
Measuring range | 0~100% | |||
Resolution | 1% | |||
Accuracy | 70~100% (±2%) | |||
Alarm system | Audio-video alarm | |||
Pulse rate range | 0~300bpm | |||
TEMP | Channel | 2 | ||
Measuring and Alarm Range | 0~50ºC | |||
Resolution | 0.1ºC | |||
Accuracy | 0.1ºC | |||
Actualization interval | about 1 Second. | |||
Average Time Constant | <10 Second. |