Explore how to effectively interpret results and readings from the YR06229 Electric Operating Table, including technical specifications and practical insights f

3D available

Understanding Measurement Interpretation with the YR06229 Electric Operating Table

The YR06229 Electric Operating Table is designed to facilitate a range of surgical procedures with precision and comfort. However, understanding how to accurately interpret its various settings and readings is crucial for healthcare professionals. This article delves into the technical specifications, operational features, and best practices for utilizing the YR06229 effectively.

Technical Overview of the YR06229 Electric Operating Table

FeatureSpecification
ModelYR06229
Length/Width2100mm/500mm
Height Adjustment (Electric)680-980 mm
Trendelenburg (Electric)±30°
Lateral Tilt (Electric)±20°
Back Section (Electric)70°/-30°
Head Board (Manual)45°/-90°
Leg Board (Manual)15°/-90°
Table Top Longitudinal Moving (Electric)300 mm
Built-in Kidney Elevator (Manual)0-120 mm

Principles of Operation

The YR06229 Electric Operating Table operates primarily through electric motors that enable smooth and precise adjustments for height, tilt, and positioning. These adjustments are pivotal for ensuring patient safety and comfort during surgical procedures. The ability to move the table longitudinally by 300 mm significantly enhances the versatility of the table for various surgical approaches, including X-ray examinations and C-arm usage.

Understanding the operating principles helps users to troubleshoot and optimize the table’s functionality. For instance, if the table does not adjust as expected, operators can diagnose potential issues with the electric motor or control panel, ensuring that surgical procedures are not compromised.

Measurement Interpretations and Readings

Interpreting measurements from the YR06229 involves understanding the various adjustments and their impact on surgical outcomes. The height adjustment ranges from 680 mm to 980 mm, allowing for optimal ergonomics for surgical staff. The Trendelenburg and lateral tilt features facilitate specific surgical needs, such as improving blood flow during certain procedures.

Each adjustment should be calibrated based on the specific requirements of the surgery being performed. For example, a greater angle of Trendelenburg may be required in abdominal surgeries to promote venous return from the lower extremities. Understanding these settings helps prevent misinterpretations that could lead to surgical complications.

Common Misinterpretations and How to Avoid Them

Healthcare professionals may encounter misinterpretations when using the YR06229 Electric Operating Table. Common issues include incorrect height settings leading to discomfort for the surgical team or inappropriate tilt angles affecting patient safety.

  • Incorrect Height Settings: Always double-check the height before initiating surgery. Use the electric adjustments to ensure the optimal height for the procedure.
  • Miscalibrated Tilt Angles: Review surgical protocols to understand the necessary angles for each specific surgery.
  • Failure to Monitor Adjustments: Continuously monitor adjustments during surgery to respond to any complications or changes in patient condition.

Technical Troubleshooting

Understanding how to troubleshoot the YR06229 is essential for maintaining operational continuity. Below are common issues, their probable causes, and solutions:

SymptomProbable CauseSolution
Table does not power onPower cable failureCheck the power connection and replace the cable if necessary.
Height adjustment not functioningElectric motor malfunctionInspect motor connections and consult service manual for troubleshooting steps.
Inconsistent height readingsCalibration issuesRun calibration procedure as per operational manual.

Best Practices for Operational Efficiency

To maximize the operational efficiency of the YR06229 Electric Operating Table, adhere to the following best practices:

  • Regularly schedule maintenance checks to ensure all electrical components function properly.
  • Train all staff thoroughly on the table's functions and troubleshooting procedures.
  • Document any issues and resolutions in a maintenance log for future reference.

Frequently Asked Questions

What are the main features of the YR06229 Electric Operating Table?

The YR06229 Electric Operating Table features electric height adjustment, Trendelenburg and lateral tilt capabilities, and manual adjustments for the head and leg boards. The table is designed for various surgical procedures, enhancing both safety and comfort.

How do I interpret the height measurements on the YR06229?

The height measurements range from 680 mm to 980 mm, which must be set according to the surgical team's needs for optimal ergonomics. Ensure that the height is adjusted correctly before starting any procedure.

What should I do if the table does not respond to adjustments?

If the table does not respond, check the power supply and ensure the motors are functioning properly. If problems persist, consult the service manual or contact technical support for assistance.

Can the YR06229 accommodate various surgical positions?

Yes, the YR06229 is designed to accommodate various surgical positions with its electric and manual adjustments. Understanding how to use these features effectively is essential for optimal surgical outcomes.

What maintenance is required for the YR06229 Electric Operating Table?

Regular maintenance should include checking electrical connections, calibrating settings, and inspecting for wear and tear. Document all maintenance activities for efficient record-keeping.

How can I ensure accurate readings and measurements?

Ensure that all settings are calibrated correctly before procedures begin. Continuous monitoring during surgery is also recommended to adapt to any changes or unexpected situations.

Where can I find replacement parts for the YR06229?

Replacement parts can be obtained through authorized suppliers or directly from the manufacturer. Always ensure that the parts are compatible with the YR06229 model.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.