Description
The Surgical Navigation Systems YR02143 is a state-of-the-art computer-aided electromagnetic navigation system designed to enhance surgical visualization, planning, and precision. This advanced system is especially beneficial for cranial procedures, including neurological and ENT surgeries, where minimizing trauma to surrounding brain tissue and reducing surgical complications are critical. The YR02143 offers exceptional precision with a spatial resolution of 1.0mm, thanks to its sophisticated optical tracking system that monitors the real-time 3D positioning of surgical tools. Compatible with tomographic images in DICOM format captured via CT, C-arm, MRI, and fMRI, this system ensures comprehensive surgical convenience and accuracy.
Market Price
The cost of surgical navigation systems like the YR02143 varies significantly, typically ranging between $100,000 and $300,000 depending on the features and functionalities. It’s crucial to consider the value this system adds to surgical precision and safety when evaluating its price. For a detailed quotation, you can generate an instant quote using the Kalstein Plus platform.
Frequently Asked Questions
Q: Is the YR02143 suitable for minimally invasive surgeries?
A: Yes, the YR02143 system is particularly adept at handling minimally invasive surgeries, making it ideal for procedures involving deep intracranial lesions and low-volume lesions.
Q: Can the system handle unexpected power outages?
A: Absolutely, the YR02143 system automatically saves patient image data and registration information, allowing for seamless continuation of the surgical process in case of power interruptions.
Advantages and Disadvantages
The YR02143 system offers numerous advantages, including high precision, reduced surgical trauma, and automatic data saving. However, its complexity may require thorough training for optimal use. While its advanced features are beneficial, the initial investment can be high, justifying its cost with the long-term benefits of enhanced surgical outcomes.
Product Use in the Field
The YR02143 system is actively used in various surgical settings, particularly for ENT and neurological procedures. Its ability to adapt to unexpected anatomical changes during surgery ensures that it remains a reliable tool for surgeons aiming for precision and safety.
Recommendations
For optimal use, it’s recommended to undergo comprehensive training on the YR02143 system. Regular software updates and maintenance checks are also advised to ensure continuous peak performance. Users should consult the Kalstein Plus platform for any additional support and to request customized configurations.
Features
– High precision with 1.0mm spatial resolution.
– Compatible with DICOM images: CT, C-arm, MRI, fMRI.
– Intelligent software for real-time adaptation.
– Four navigation modes for comprehensive process monitoring.
Technical Specifications
Model | YR02143 | ||
Component | Amount | Description | |
Optical tracking system | |||
NDI tracking system | 1 set | Track 3D position and orientation of active or passive markers attached to surgical tools | |
Image management workstation | |||
Computer system | 1 set | For 2D image fusion and 3D reconstruction, navigation system | |
Touch monitor | 1 piece | 19 “, 1280 x 1024 resolution, medical and healthcare grade | |
Software package | 1 set | Core set (image fusion, surgical planning and navigation, data management) | |
Software version 1 | 1 piece | Diffusion-tensor-images navigation module | |
Software version 2 | 1 piece | Needle-Aspiration-Biospy navigation module | |
Mobile car | |||
Support trolley with 4 wheels | 1 piece | To support the optical tracking system and image management workstation | |
Surgical tools | |||
Navigation probe | 2 pieces | To help the optical measurement system track movement | |
Microscope probe | 1 piece | To help the optical measurement system track movement | |
Active marker | 6 pieces | To help quickly recognize critical anatomical structures. | |
Passive reflective sphere | 10 pieces | To reflect the infrared laser for cameras (in the optical tracking system) to capture | |
Framework | 2 pieces | To locate passive reflective sphere with 4 pins | |
Articulated arm | 1 piece | To hold the frame of reference | |
Clamp adapter | 2 pieces | For the adaptation of another instrument (such as the brain needle during navigation) | |
Foot-switch | 1 piece | To help register and navigate | |
Touchmonitor specification | |||
Case / bezel color | Beige | Mini VGA D-sub 15-pin; DVI-D | Mini VGA D-sub 15-pin; DVI-D |
Display | Sixe: 19.0 ”diagonal, active matrix TFT | Horizontal: 31.5-80 kHz | Horizontal: 31.5-80 kHz |
Aspect ratio: 5; 4 | Vertical: 56.3-75 Hz | Vertical: 56.3-75 Hz | |
Useful display area | Horizontal: 14.82 “(376.32 mm) | Type: 100-240 VAC, 50-60 Hz | Type: 100-240 VAC, 50-60 Hz |
Vertical: 11.85 “(301.06 mm) | Internal DC input power supply | Internal DC input power supply | |
Monitor dimensions | Width: 429mm (16.9 “) | DC input voltage (line): 12V 3.6V | DC input voltage (line): 12V 3.6V |
Height (including stand): 15.21 “(386 mm) | 48 W max. | 48 W max. | |
Depth (inc. Base) | Operating; 0 ° C to 40 ° C | Operating; 0 ° C to 40 ° C | |
Native resolution (optional) | 1280 x 1024 @ 60/70/75 Hz | Storage: -20 ° C to 60 ° C | Storage: -20 ° C to 60 ° C |
Other supported resolutions | 1280 x 960 / 1,024 x 768 in Hz | Operating: 20% -80% | Operating: 20% -80% |
Colors | 16.7 million | Storage: 10% -90% | Storage: 10% -90% |
Brightness | LCD panel: 300 cd / m2 | Actual: 17.66 lbs. (8 kg) | Actual: 17.66 lbs. (8 kg) |
With AccuTouch: 246 cd / m2 | Shipping: 25.10 lbs (11.84) | Shipping: 25.10 lbs (11.84) | |
With IntellTouch: 276 cd / m2 | 3 years | 3 years | |
Response time | 20 msec (typical) | Typical 40,000 hours at half brightness | Typical 40,000 hours at half brightness |
Vision angle | Horizontal (left / right): 89 ° / 89 ° | MTBF; 50,000 hours demonstrated | MTBF; 50,000 hours demonstrated |
(Typical, from the center) | Vertical (up / down): 89 ° / 89 ° | UL, Cul, fcc, ic, ce, China RoHS, Argentina S mark | UL, Cul, fcc, ic, ce, China RoHS, Argentina S mark |
Contrast ratio | 1300: 1 (typical) | Two watt / channel speakers located in the display head | Two watt / channel speakers located in the display head |
Input video format | Analog: (no video card needed) | OSD locks for user and power controls | OSD locks for user and power controls |
Input sync format | Separate horizontal and vertical | OSD extras include volume, treble, bass, balance | OSD extras include volume, treble, bass, balance |
Synchronization, compound synchronization and | OSD Language (English, Chinese, Spanish, French) | OSD Language (English, Chinese, Spanish, French) | |
Synchronization in green | Safety lock receptacle | Safety lock receptacle |