Description
The Patient Monitors YR02176 is a highly sophisticated medical device designed for comprehensive patient monitoring in critical care environments such as Operating Theatres (OT) and Intensive Care Units (ICU). This monitor boasts a 15-inch LCD screen and a modular parameter configuration that offers standard monitoring for ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. Its versatility is further enhanced with optional features including Masimo/Nellcor SpO2, Dual-IBP, AG, C.O., BIS, 3/12-lead ECG, among others, making it an indispensable tool in modern healthcare settings. Request a quote today through Kalstein Plus and experience cutting-edge medical technology efficiency!
Market Price
The Patient Monitors YR02176 is competitively priced in the market, ranging from approximately $4,200 to $5,000 USD. This price range reflects the advanced technology and reliable performance of the unit, making it a valuable investment in critical healthcare equipment.
Frequently Asked Questions
What are the standard parameters monitored by YR02176?
The standard parameters include ECG, SPO2, TEMP, NIBP, RESP, and PR/HR.
Can the Patient Monitors YR02176 be used in pediatrics?
Yes, the monitor is suitable for use in both pediatric and adult patient monitoring.
What optional features are available?
Optional features include Masimo/Nellcor SpO2, Dual-IBP, AG, C.O., BIS, among others, catering to specific monitoring needs.
Advantages and Disadvantages
Advantages:
– High-resolution 15-inch LCD screen for clear visibility.
– Modular design allows customization based on clinical needs.
– Comprehensive parameter monitoring ensures accurate patient assessment.
– User-friendly interface for seamless operation.
Disadvantages:
– Initial investment cost might be higher than less sophisticated monitors.
– Requires training for optimal use and interpretation of advanced data.
Field Usage
In practical scenarios, the Patient Monitors YR02176 provides real-time and precise monitoring, essential in critical situations such as surgeries or intensive care. Its modular configuration allows clinicians to tailor the monitoring process according to specific patient needs, ensuring optimal patient care.
Recommendations
To ensure the longevity and optimal performance of the Patient Monitors YR02176, regular maintenance and calibration are recommended. Ensure that all healthcare staff are adequately trained to operate the device and interpret the data accurately. It is also advised to update the software periodically to benefit from new features and improvements.
Features
- 15 inch LCD screen for clear visibility.
- Modular design for customizable parameter monitoring.
- Standard parameters: ECG, SPO2, TEMP, NIBP, RESP, PR/HR.
- Optional advanced configurations for specialized monitoring.
- User-friendly interface ensuring ease of use.
- Audio-video alarm system for immediate alerts.
Technical Specifications
Model | YR02176 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate | Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration | Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Resp. Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP | Method | Oscillometric |
Mode | manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP | Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization Interval | about 1 Second. | |
Average Time Constant | <10 Second. |